LEGEND MAX™ α-Synuclein Aggregate ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
α-synuclein oligomer, oligomeric α-synuclein, SNCA fibrillar aggregates
Ave. Rating
Submit a Review
Product Citations
publications
LEGEND-MAX_alpha-Synuclein-Aggregate-_ELISA_Kit_02142
Representative sandwich immunoassay standard curve generated using serial dilutions of LEGEND MAX™ α-Synuclein Aggregate standard ranging from 156.25 pg/mL to 10,000 pg/mL.
  • LEGEND-MAX_alpha-Synuclein-Aggregate-_ELISA_Kit_02142
    Representative sandwich immunoassay standard curve generated using serial dilutions of LEGEND MAX™ α-Synuclein Aggregate standard ranging from 156.25 pg/mL to 10,000 pg/mL.
Cat # Size Price Quantity Check Availability Save
449407 1 Pre-coated Plate £418
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

α-Synuclein is a 140 amino acid protein involved in the pathology of multiple neurodegenerative diseases, including Parkinson’s disease and multiple system atrophy (MSA). This protein localizes to presynaptic terminals in neurons, where it is implicated in regulating neurotransmitter release. α-Synuclein can exist in multiple conformations: monomers, aggregates (formed from monomers), and fibrils (generated from aggregates). These fibrils are the major component of Lewy bodies, which are a hallmark of Parkinson’s disease and other dementias. Aggregates of α-synuclein are thought to be toxic, since they can spread to other neurons and can promote additional α-synuclein aggregation and Lewy body formation. Therefore, measurement of α-synuclein aggregates in biological samples is an important tool for neurodegenerative disease research.

The BioLegend LEGEND MAX™ α-Synuclein Aggregate ELISA Kit is a sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with rat monoclonal anti-α-synuclein aggregate antibody. The detection antibody is a biotinylated goat polyclonal anti-α-synuclein aggregate antibody. This kit is specifically designed for the accurate quantitation of α-synuclein aggregates in tissue and cell lysates (ex. human brain lysates, transgenic mouse brain lysates) and human cerebrospinal fluid. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • α-Synuclein Aggregate Pre-coated 96-well Strip Microplate
  • α-Synuclein Aggregate Detection Antibody
  • α-Synuclein Aggregate Lyophilized Standard
  • Avidin-HRP
  • Reagent Diluent (2X)
  • Wash Buffer (20X)
  • Substrate Solution F 
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human, Mouse
Application

ELISA

Sensitivity
44.9 ± 18.9 pg/mL
Standard Range
156.25 – 10,000 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1000 µL
  • Microplate shaker
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Polypropylene vials

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 02/14/2023

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account