Purified anti-human CD31 Antibody

Pricing & Availability
Clone
W18200D (See other available formats)
Regulatory Status
RUO
Other Names
PECAM-1, EndoCAM
Isotype
Rat IgG2a, λ
Ave. Rating
Submit a Review
Product Citations
publications
W18200D_PURE_CD31_Antibody_091720
Human peripheral blood granulocytes were stained with purified anti-human CD31 (clone W18200D) (filled histogram) or purified rat IgG2a, λ Isotype control (open histogram), followed by goat anti-rat IgG PE.
  • W18200D_PURE_CD31_Antibody_091720
    Human peripheral blood granulocytes were stained with purified anti-human CD31 (clone W18200D) (filled histogram) or purified rat IgG2a, λ Isotype control (open histogram), followed by goat anti-rat IgG PE.
Cat # Size Price Quantity Check Availability Save
375902 100 µg $80.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD31 is a 130-140 kD type I transmembrane glycoprotein also known as platelet endothelial cell adhesion molecule-1 (PECAM-1) or Endocam. It is expressed on monocytes, platelets, granulocytes, endothelial cells and lymphocyte subsets. CD31 has been reported to bind CD38 and be involved in wound healing, angiogenesis, and cellular migration in an inflammatory situation.

Product Details
Technical data sheet

Product Details

Reactivity
Human
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
Recombinant human CD31 protein
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 1.0 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

Clone W18200D antibody does not affect target binding of clone WM59 and vice versa.

RRID
AB_2888894 (BioLegend Cat. No. 375902)

Antigen Details

Structure
Ig superfamily, type I transmembrane glycoprotein, 130-140 kD
Distribution

Monocytes, platelets, granulocytes, endothelial cells, lymphocyte subset

Function
Cell adhesion, signal transduction
Ligand/Receptor
CD38
Cell Type
Endothelial cells, Granulocytes, Lymphocytes, Monocytes, Neutrophils, Platelets
Biology Area
Angiogenesis, Cell Adhesion, Cell Biology, Immunology, Neuroinflammation, Neuroscience
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. DeLisser H, et al. 1994. Immunol. Today 15:490.
2. Newman P, 1997. J. Clin. Invest. 99:3.
3. Fawcett J, et al. 1995. J. Cell Biol. 128:1229.

Gene ID
5175 View all products for this Gene ID
UniProt
View information about CD31 on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 09/17/2020

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere
Insert Note Here
Save Close Clear
Lab Timer
Tools
Login/Register
Remember me
Forgot your password? Reset Password
Request an Account