LEGENDplex™ Human Angiopoietin-2 Capture Bead A6, 13X

Pricing & Availability
Regulatory Status
RUO
Other Names
Angiopoietin 2, ANG-2, Angiopoietin-2B, Angiopoietin-2a, Angiopoietin-2, Tie2-Ligand, AGPT2, ANG2, ANGPT2
Ave. Rating
Submit a Review
Product Citations
publications
1_740702-Ang-2-Solo-Curve
Data generated using the following LEGENDplex™ Mix & Match Reagents:

• Human Angiopoietin-2 Capture Bead A6, 13X (Cat. # 740702)
• Human Angiogenesis Panel 1 Detection Antibodies (Cat. # 740700)
• Human Angiogenesis Panel 1 Standard (Cat. # 740699)
• Buffer Set I (Cat. # 740623)

Note: Data acquired on a BD FACSCalibur™ flow cytometer.
  • 1_740702-Ang-2-Solo-Curve
    Data generated using the following LEGENDplex™ Mix & Match Reagents:

    • Human Angiopoietin-2 Capture Bead A6, 13X (Cat. # 740702)
    • Human Angiogenesis Panel 1 Detection Antibodies (Cat. # 740700)
    • Human Angiogenesis Panel 1 Standard (Cat. # 740699)
    • Buffer Set I (Cat. # 740623)

    Note: Data acquired on a BD FACSCalibur™ flow cytometer.
  • 2_740702-ANG-2-Detectability
    Human plasma samples (n = 80) were quantified using the following LEGENDplex™ Mix & Match Reagents:

    • Human Angiopoietin-2 Capture Bead A6, 13X (Cat. # 740702)
    • Human Angiogenesis Panel 1 Detection Antibodies (Cat. # 740700)
    • Human Angiogenesis Panel 1 Standard (Cat. # 740699)
    • Buffer Set I (Cat. # 740623)

    Data are presented as Mean + SD. Plasma samples were provided courtesy of Professor Huaizhu Wu, Baylor College of Medicine.
Cat # Size Price  
This product has been discontinued. The Cat. No. for the replacement is 741217.

Please contact Sales regarding the availability of this discontinued product for purchase as a custom product.

Didn't find what you were looking for? Try using our Advanced Search to find products.

Would you like to recommend a new product? Contact our business development team.

Would you like a custom conjugated antibody product? Contact our custom solutions team.
Description

The LEGENDplex™ Human Angiogenesis Panel 1 Mix and Match Capture Beads offer flexible customization within the panel (12-plex) using the following items listed below:

740597 LEGENDplex™ Human IL-6 Capture Bead A4, 13X
740701 LEGENDplex™ Human Angiopoietin-1 Capture Bead A5, 13X
740702 LEGENDplex™ Human Angiopoietin-2 Capture Bead A6, 13X
740703 LEGENDplex™ Human EGF Capture Bead A7, 13X
740704 LEGENDplex™ Human IL-34 Capture Bead A10, 13X
740705 LEGENDplex™ Human FGF-basic Capture Bead A10, 13X
740706 LEGENDplex™ Human CXCL8 (IL-8) Capture Bead B2, 13X
740707 LEGENDplex™ Human PECAM-1 Capture Bead B3, 13X
740708 LEGENDplex™ Human PlGF Capture Bead B4, 13X
740710 LEGENDplex™ Human VEGF Capture Bead B6, 13X
740711 LEGENDplex™ Human TNF-α Capture Bead B7, 13X
740712 LEGENDplex™ Human G-CSF Capture Bead B9, 13X

Selected items will be used together with:

740699 LEGENDplex™ Human Angiogenesis  Panel 1 Standard
740700 LEGENDplex™ Human Angiogenesis  Panel 1 Detection Antibodies
740623 LEGENDplex™ Buffer Set I
740377 LEGENDplex™ Filter Plate or 740379 LEGENDplex™ V-bottom Plate

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Application

Multiplex


Learn more about LEGENDplex™ at biolegend.com/legendplex

Download the LEGENDplex™ software here.

Antigen Details

Biology Area
Angiogenesis, Cell Adhesion, Cell Biology, Immunology, Innate Immunity, Signal Transduction
Molecular Family
Cytokines/Chemokines, Growth Factors
Gene ID
285 View all products for this Gene ID
Specificity (DOES NOT SHOW ON TDS):
Angiopoietin-2
Specificity Alt (DOES NOT SHOW ON TDS):
Angiopoietin-2
App Abbreviation (DOES NOT SHOW ON TDS):
Multiplex - Component
UniProt
View information about Angiopoietin-2 on UniProt.org

Related FAQs

If I don't have a vacuum, how do I remove the liquid from my plate?

If you do not have a vacuum, the assay should be run in a V-bottom plate. After centrifugation using a swinging-bucket rotor with a plate adaptor, you can remove the liquid by flicking the plate quickly, dumping the contents into a sink, and patting it dry carefully on a stack of clean paper towels without losing the beads. Alternatively, you can remove the liquid by using a pipette.

Should I perform the assay with the filter plates or with V-bottom plates?

Filter plates or V-bottom plates have been included in some kits for your convenience. A vacuum filtration unit is required to work with the filter plates. However, if you don’t have access to a vacuum manifold or if you prefer, then you can use the V-bottom plates and follow the recommended assay protocols for the type of plates you choose. All plates should be made from low binding polypropylene. Polystyrene ELISA or cell culture plates should not be used.

After I finish the staining process, how long can I wait before reading my LEGENDplex™ samples?

The samples can be kept overnight at 4°C while being protected from exposure to light and be read the next day. There may be a decrease in signal, but overall, the assay results should not be affected. Storing the samples for extended periods of time is not recommended, as it could lead to further reductions in signal.

What is the shelf life of LEGENDplex™ kits?

LEGENDplex™ kits are guaranteed for 6 months from the date of receipt, but may have a shelf life of up to 2 years from the date of manufacture.

Is special software required for data analysis?

Typically flow cytometers generate output files in FCS format (e.g. FCS 2.0, 3.0, or 3.1) and in some cases in list mode file format (LMD). Other software may be available to analyze FCS files. Data generated using LEGENDplex™ kits can be analyzed using the freely available LEGENDplex™ data analysis software. Please check our website for the most updated versions of the software.

Go To Top Version: 1    Revision Date: 03/01/2018

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account