PE/Cyanine7 anti-mouse IgMa Antibody

Pricing & Availability
Clone
MA-69 (See other available formats)
Regulatory Status
RUO
Other Names
Igh-6a
Isotype
Mouse (C57BL/6) IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
MA-69_PECy7_IgMa_Antibody_031318
BALB/c mouse spenocytes were stained with PE/Cyanine7 IgMa (Clone MA-69, closed histogram) or PE/Cyanine7 mouse IgG1, ? Isotype control (open histogram).
  • MA-69_PECy7_IgMa_Antibody_031318
    BALB/c mouse spenocytes were stained with PE/Cyanine7 IgMa (Clone MA-69, closed histogram) or PE/Cyanine7 mouse IgG1, ? Isotype control (open histogram).
See PE/Cyanine7 spectral data
Cat # Size Price Quantity Avail. Save
408609 25 µg 100€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
408610 100 µg 220€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

This antibody was raised by immunization with IgMa mAb TC31. It specifically reacts with mouse IgM of Igh-Ca and the related haplotypes (c, f, g, h, and j). It has been reported that beads coated with MA-69 antibody can stimulate B cell proliferation.

Product Details
Technical Data Sheet (pdf)

Product Details

Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with PE/Cyanine7 under optimal conditions.
Concentration
0.2 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is = 0.25 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application Notes

Additional reported applications (for the relevant formats) include: ELISA as capture antibody or detection antibody, stimulation of B cell proliferation, and immunohistochemistry of acetone-fixed frozen sections.

Additional Product Notes
BioLegend is in the process of converting the name PE/Cy7 to PE/Cyanine7. The dye molecule remains the same, so you should expect the same quality and performance from our PE/Cyanine7 products. Please contact Technical Service if you have any questions.
Application References
  1. Sieckmann D, et al. 1991. Hybridoma 10:121.
  2. Stall AM. 1996. Weir's Handbook of Experimental Immunology pp. 27.
Product Citations
  1. Lazarian G, et al. 2021. Cancer Cell. 39(3):380-393.e8. PubMed
RRID
AB_2728433 (BioLegend Cat. No. 408609)
AB_2728434 (BioLegend Cat. No. 408610)

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 03/13/2018

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.