Description

Interferon alpha-2 (IFN-α2) is a cytokine encoded by the IFNA2 gene located on chromosome 9. It belongs to the Type 1 IFN family which includes 13 α subtypes, 1 β, and 1 ω. IFN-α2 was the first of these subtypes to be produced pharmaceutically and is the most widely studied. The mature secreted protein consists of 165 amino acids with 5 α-helices and two disulfide bonds. There are a several allelic variants of IFN-α2, including IFN-α2a, IFN-α2b, and IFN-α2c. IFN-α2 can act on all cell types due to the ubiquitous expression of the Type 1 IFN receptor (IFNAR).
 

IFN-α2 acts to combat infection by stimulating the production of proteins that inhibit viral replication and prevent viral entry into neighboring cells. IFN-α2 can stimulate the immune system by initiating T and NK cell mediated cytotoxicity. IFN-α2 also can inhibit cancer cell proliferation and activate immune system to target cancer cells. IFN-α2 has been used therapeutically in a variety of viral infections (including hepatitis B and C) and certain cancers (such as melanoma, renal cell carcinoma).


BioLegend's LEGEND MAX™ Human IFN-α2 ELISA kit is a Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with a monoclonal mouse anti-human IFN-α2 capture antibody. The detection antibody is a biotinylated monoclonal mouse anti-human IFN-α2 antibody. This kit is specifically designed for the accurate quantitation of human IFN-α2 from cell culture supernatant, serum, plasma and other biological fluids. Different IFN-α2 allelic variants can be detected equally. It is analytically validated with ready-to-use reagents.

Product Details
Technical Data Sheet (pdf)

Kit Contents

Kit Contents
  • Anti-Human IFN-α2 Pre-coated 96-well Strip Microplate
  • Human IFN-α2 Dectection Antibody
  • Human IFN-α2 Standard
  • Matrix A
  • Avidin-HRP
  • Assay Buffer G
  • Wash Buffer (20X)
  • Substrate Solution F
  • Stop Solution
  • Plate Sealers

Product Details

Reactivity
Human
Application

ELISA

Sensitivity
The minimum detectable concentration of IFN-α2 is 2.94±0.89 pg/mL with assay buffer (n=9), and 2.57±0.64 pg/mL with Matrix A (n=10). The sensitivities shown are ± one standard deviation.
Standard Range
15.6 - 1000 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1,000 µL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Polypropylene tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Biology Area
Immunology, Innate Immunity
Molecular Family
Cytokines/Chemokines
Gene ID
3440 View all products for this Gene ID
UniProt
View information about IFN-alpha2 on UniProt.org

Related FAQs

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

Dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The Wash buffer is the same for all the current LEGEND MAX™ kits. All the part numbers on the Wash Buffer bottles in these kits should be the same. For ELISA MAX™ Deluxe and ELISA MAX™ Standard sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

In your LEGEND MAX™ ELISA Kits, there is a step that calls for a washing of the plates before even adding any sample to it. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The washings were designed to remove these components before you start the assay. If you do not do the washings, the effect on assay performance is negligible.

Go To Top Version: 1    Revision Date: 11.30.2018

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere
Insert Note Here
Save Close Clear
Lab Timer
Tools
Login / Register
Forgot your password? Reset password?
Create an Account