Zombie UV™ Fixable Viability Kit

Pricing & Availability
Other Names
Fixable Dye, Fixable Viability Dye
Ave. Rating
6 reviews
Product Citations
publications
Zombie_UV_Viability_Dye_012714
One day old C57BL/6 mouse splenocytes were stained with Zombie UV™ and analyzed before fixation (purple) or after fixation and permeabilization (red). Cells alone, without Zombie UV™ staining, are indicated in black.
  • Zombie_UV_Viability_Dye_012714
    One day old C57BL/6 mouse splenocytes were stained with Zombie UV™ and analyzed before fixation (purple) or after fixation and permeabilization (red). Cells alone, without Zombie UV™ staining, are indicated in black.
See Zombie UV™ spectral data
Cat # Size Price Quantity Avail. Save
423107 100 tests 60€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
423108 500 tests 228€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Zombie UV™ is an amine reactive fluorescent dye that is non-permeant to live cells, but permeant to the cells with compromised membranes. Thus, it can be used to assess live vs. dead status of mammalian cells. Zombie UV™ is a polar water soluble dye, providing violet fluorescence, making it suitable for multi-color detection.

Product Details
Technical Data Sheet (pdf)

Product Details

Preparation
Zombie UV™ Fixable Viability kit is composed of lyophilized Zombie UV™ dye and anhydrous DMSO. For reconstitution, bring the kit to room temperature; add 100 µl of DMSO to one vial of Zombie UV™ dye until fully dissolved. 100 tests = 1 vial of Zombie UV™ + DMSO, 500 tests = 5 vials of Zombie UV™ + DMSO.
Storage & Handling
Store kit at -20°C upon receipt. Do not open vials until needed. Once the DMSO is added to the Zombie UV™ dye, use immediately, or store at -20°C in a dry place and protected from light, preferably in a desiccator or in a container with desiccant for no more than one month. The unopened kit is guaranteed for six months.

This product has a shelf-life of 12 months or less. Please contact our technical support team for lot specific CoA and expiration date inquiries of this product.
Application

FC, ICFC - Quality tested

Recommended Usage

Each lot of this product is quality control tested by immunofluorescent staining with flow cytometric analysis.

For flow cytometry, the suggested dilution is 1:100-1:1000 for 1-10 million cells. It is recommended that the reagent be titrated for optimal performance for each application, as optimal dosage varies with cell type.

Excitation Laser
Ultraviolet Laser (360 nm)
Application Notes

Standard Cell Staining Protocol:

  1. Prior to reconstitution, spin down the vial of lyophilized reagent in a microcentrofuge to ensure the reagent is at the bottom of the vial.
  2. For reconstitution, pre-warm the kit to room temperature; add 100 µl of DMSO to one vial of Zombie UV™ dye and mix until fully dissolved
  3. Wash cells with PBS buffer (no Tris buffer and protein free).
  4. Dilute Zombie UV™ dye at 1:100-1000 in PBS. Resuspend 1-10 x 106 cells in diluted 100 µl Zombie UV™ solution. To minimize background staining of live cells, titrate the amount of dye and/or number of cells per 100 µl for optimal performance. Different cell types can have a wide degree of variability in staining based on cell size and degree of cell death.

    Note: Don’t use Tris buffer as a diluent and be sure that the PBS does not contain any other protein like BSA or FBS.
    Note: The amount of dye used can also influence the ability to detect apoptotic as well as live and dead cells.

  5. Incubate the cells at room temperature, in the dark, for 15-30 minutes.
  6. Wash one time with 2 ml BioLegend’s Cell Staining Buffer (Cat. No. 420201) or equivalent buffer containing serum or BSA.
  7. Continue performing antibody staining procedure as desired.
  8. Cells can be fixed with paraformaldehyde or methanol prior to permeabilization or can be analyzed without fixation.

No-wash Sequential Staining Protocol:

  1. Wash cells with PBS buffer (no Tris buffer and protein free).
  2. For reconstitution, pre-warm the kit to room temperature; add 100 µl of DMSO to one vial of Zombie UV™ dye and mix until fully  dissolved
  3. Determine the total µl volume of antibody cocktail previously titrated and optimized for the assay that will be added to each vial/well of cells based on a final volume of 100 µl. Subtract that antibody volume from the 100 µl total staining volume intended for the assay. In the remaining volume, dilute Zombie UV™ dye at 1:100-1000 in PBS as determined by prior optimization at that volume. For example, if you are adding 20 µl of antibody cocktail for a 100 µl total staining volume, use 80 µl of Zombie UV™ solution. Resuspend 1-10 x 106 cells in the appropriate volume of Zombie UV™ solution. Different cell types can have a wide degree of variability in staining based on cell size and degree of cell death.

    Note: Don’t use Tris buffer as a diluent and be sure that the PBS does not contain any other protein like BSA or FBS.
    Note: The amount of dye used can also influence the ability to detect apoptotic as well as live and dead cells.

  4. Incubate for 10-15 minutes at RT, protected from light. Without washing the cells, add the cell surface antibody cocktail and incubate for another 15-20 minutes.
  5. Add 1-2 mL Cell Staining Buffer (Cat. No. 420201) or equivalent buffer containing BSA or serum. Centrifuge to pellet.
  6. Continue with normal fixation and permeabilization procedure. If planning to skip fixation and analyze cells live, complete an additional wash step to minimize any unnecessary background of the live cells.


Notes: If the cell type in use cannot tolerate a protein-free environment, then titrate the Zombie UV™ dye in the presence of the same amount of BSA/serum as will be present in the antibody staining procedure. A higher amount of Zombie UV™ may be required since the BSA/serum will react with and bind up some proportion of the Zombie UV™.

Zombie UV™ dye is excited by the UV laser (350 nm) and has fluorescence emission maximum at 459 nm. If using in a multi-color panel design, filter optimization may be required depending on other fluorophores used. Zombie UV™ dye has similar emission to DAPI.

 

Application References
  1. Souza-Fonesca-Guimaraes F, et al. 2015. PNAS. 112:2376. PubMed
Product Citations
  1. Souza-Fonseca-Guimaraes F, et al. 2015. Proc Natl Acad Sci U S A. 112:2376. PubMed
  2. Matsui K, et al. 2015. PLoS One. 10: 0137195. PubMed
  3. Giles D, et al. 2016. PLoS One. 11: 0149783. PubMed
  4. Lacar B, et al. 2016. Nat Commun. 7: 11022. PubMed
  5. Souza-Fonseca-Guimaraes F, et al. 2016. Cell Death Dis. 7:e2302. PubMed
  6. Comte D, et al. 2016. Proc Natl Acad Sci U S A. 113: 9321 - 9326. PubMed
  7. Capuccini B, et al. 2016. Sci Rep. 6:39258. PubMed
  8. Rao S, et al. 2017. Cell. 168(3):503-516.e12. PubMed
  9. Salehi S, et al. 2017. PLoS One. 10.1371/journal.pone.0163614. PubMed
  10. Lin J, et al. 2017. Sci Rep. 7:41722. PubMed
  11. Xu H, et al. 2017. EBioMedicine. 10.1016/j.ebiom.2017.03.003. PubMed
  12. Grabiec A, et al. 2017. J Allergy Clin Immunol. 10.1016/j.jaci.2017.03.024. PubMed
  13. Leigh N, et al. 2017. The Journal of Immunology. 10.4049/jimmunol.1502181. PubMed
  14. Kallert S, et al. 2017. Nature Communications. 10.1038/ncomms15327. PubMed
  15. An J,et al. 2017. Sci Rep.. 10.1038/s41598-017-13629-0. PubMed
  16. Clarke F,et al. 2017. PLoS One. 10.1371/journal.pone.0186625. PubMed
  17. Littwitz-Salomon E, Schimmer S, and Dittmer U. 2017. J Virol. 10.1128/JVI.01122-17. PubMed
  18. Fredriksson-Lidman K, et al. 2017. PLoS One. 10.1371/journal.pone.0185509. PubMed
  19. Zgair A, et al. 2017. Sci Rep. . 10.1038/s41598-017-15026-z. PubMed
  20. O’Neill R, et al. 2017. J Immunol. 10.4049/jimmunol.1700380. PubMed
  21. Moreno-Fernandez ME, et al. 2018. JCI Insight. 3. PubMed
  22. Nath PR, et al. 2019. Front Immunol. 9:2985. PubMed
  23. Poggio M, et al. 2019. Cell. 177:414. PubMed
  24. Mitchell LA, et al. 2019. Oncotarget. 10:2252. PubMed
  25. Bommareddy PK, et al. 2019. J Biol Methods. 6:2. PubMed
  26. Smith CA, et al. 2019. JCI Insight. 4. PubMed
  27. Li D, et al. 2019. J Lipid Res. 60:1503. PubMed
  28. Zeng Y, et al. 2019. Oncotarget. 10:4479. PubMed
  29. Cantor DJ et al. 2019. Cell reports. 26(1):108-118 . PubMed
Publication Library

Antigen Details

Biology Area
Apoptosis/Tumor Suppressors/Cell Death, Cell Biology, Neuroscience
Gene ID
NA

Related FAQs

Can I use methanol/ethanol for fixation after using a Zombie dye?

Yes, most fixation reagents are fine to be used with Zombie dyes. However, it should be noted that Zombie dyes can still be sensitive to reactive oxygen species. Light exposure or reagents with hydrogen peroxide can lead to free radical formation, affecting fluorescence.

Can I use your Zombie dyes for microscopy application?

Zombie dyes that have been tested for microscopy applications in-house will display data on the product webpage. It should be noted that Zombie may not work for dead cell discrimination in every microscopy application, as a complicated point will be to determine the level of Zombie signal that constitutes a dead cell. Another difficulty may be finding the proper plane for microscopy in order to observe the dead cells.

Can I use Zombie and Annexin V to detect apoptotic cells?

Yes, Zombie can be used with Annexin V to discriminate live, apoptotic, and dead cells. Cells double positive for both Zombie and Annexin V are dead, while Zombie-dim/Annexin V-positive cells are apoptotic. Live cells will be Zombie-low and Annexin V-negative. The advantage to Zombie over PI and 7-AAD is that you can now fix and/or permeabilize the cells to stain for cell surface and intracellular antigens.

Can I use Zombie with cells suspension containing serum?
Serum is full of proteins which will sequester the dye and thereby reducing its effective concentration. The basic rule of thumb with zombie is to titrate it based on your specific condition. Titration also helps reduce the background and spillover into other channels.
Can Zombie be used to determine bacteria, yeast viability?
We have not tested in house bacterial or yeast viability using Zombie dyes. It is not clear whether the difference between surface and intracellular signals will be significantly different in case of non mammalian cells.
How does the performance of your Zombie dye compare with competitors?

Zombie dyes have been tested against other leading competitors' fixable viability kits and given comparable results. We also highly recommend that you titrate down the amount of each dye used in order to best match the negative signals of your unstained sample and MFI- (mean fluorescence intensity) stained samples.

I am concerned about the spillover I am observing from the Zombie dye into its neighboring channels.
Rule of thumb with Zombie dyes is to titrate them down as much as possible to fit your application. This should potentially help with spillover. Secondly, Zombie positive events represent dead cells and are typically gated out from analysis.
Why can't I fix my cells prior to using Zombie?

The fixation process can contort and alter the membrane of cells, effectively rendering them as dead. Since the ability of Zombie to stain dead cells is correlated with cell permeability, your results may no longer be a valid representation of dead versus live cells.

Go To Top Version: 3    Revision Date: 05/30/2019

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere
Insert Note Here
Save Close Clear
Lab Timer
Tools
Login / Register
Forgot your password? Reset password?
Create an Account