Purified anti-human CD235ab Recombinant Antibody

Pricing & Availability
Clone
QA20B11 (See other available formats)
Regulatory Status
RUO
Other Names
Glycophorin A/B, GPA/GPB
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
QA20B11_PURE_CD235ab_Antibody_1_022422
Human red blood cells were stained with purified anti-human CD235ab recombinant (clone QA20B11) (filled histogram) or mouse IgG1, κ isotype control (open histogram) followed by FITC anti-mouse IgG.
  • QA20B11_PURE_CD235ab_Antibody_1_022422
    Human red blood cells were stained with purified anti-human CD235ab recombinant (clone QA20B11) (filled histogram) or mouse IgG1, κ isotype control (open histogram) followed by FITC anti-mouse IgG.
  • QA20B11_PURE_CD235ab_Antibody_2_022422
    Human paraffin-embedded placenta tissue slices were prepared with a standard protocol of deparaffination and rehydration. Antigen retrieval was done with citrate buffer 1X (10 mM, pH6.0) at 95°C for 40 minutes. The tissue was washed with PBS/ 0.05% Tween-20 twice for five minutes and blocked with 5% FBS and 0.2% gelatin for 30 minutes. Then, the tissue was stained with 5 µg/mL purified anti-human CD235ab recombinant (clone QA20B11) at 4°C overnight. On the next day, the tissue was washed twice with PBS and stained with Alexa Fluor® goat anti-mouse IgG (clone Poly4053) (red) for two hours at room temperature. The nuclei were counterstained with DAPI (blue). The image was captured with a 10X objective.
Cat # Size Price Save
382002 100 µg ¥20,680
Description

The clone QA20B11 antibody reacts with a common epitope of glycophorin A (CD235a) and glycophorin B (CD235b). Glycophorin A is a major sialoglycoprotein expressed on red blood cell membrane, and erythroid precursors. Glycophorin A shares strong homology with glycophorin B. The clone QA20B11 antibody recognizes human RBCs and erythroid precursors and is useful in erythroid cell development studies. Mature, non-nucleated red blood cells are characteristically glycophorin A positive, but CD45 and CD71 negative.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Antibody Type
Recombinant
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested
IHC-P - Verified

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.001 µg per million cells in 100 µL volume. For immunohistochemistry on formalin-fixed paraffin-embedded tissue sections, a concentration range of 2.5 - 10.0 µg/mL is suggested. It is recommended that the reagent be titrated for optimal performance for each application.

RRID
AB_2924579 (BioLegend Cat. No. 382002)

Antigen Details

Structure
Sialoglycoprotein, 20 kD
Distribution

Erythrocytes

Cell Type
Erythrocytes
Biology Area
Immunology
Molecular Family
CD Molecules
Gene ID
2993 View all products for this Gene ID
UniProt
View information about CD235ab on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 02/24/2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.