LEGENDplex™ Mouse Inflammation Panel (13-plex) with V-bottom Plate

Pricing & Availability
Regulatory Status
RUO
Other Names
IL-23, IL-1α, IFN-γ, TNF-α, CCL2 (MCP-1), IL-12p70, IL-1β, IL-10, IL-6, IL-27, IL-17A, IFN-β, GM-CSF
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Save
740446 100 tests ¥387,420
Description

Cytokines are small soluble glycoproteins that act as extracellular signaling molecuels and meidate communications between cells. They regulate immunity, inflammation and hematopoiesis as well as cell growth, migration, development and differentiation. Cytokines act in large tightly regulated networks where both the production and action of one cytokine is affected by the behavior of other cytokines. The accurate measurement of the expression profile of cytokines in a sample is critical to complete and in-depth understanding of disease progression and immune responses.


The LEGENDplex™ Mouse Inflammation Panel is a multiplex assay by using fluorescence–encoded beads suitable for the analysis on various flow cytometers. This panel allows simultaneous quantification of 13 mouse cytokines, including IL-1α, IL-1β, IL-6, IL-10, IL-12p70, IL-17A, IL-23, IL-27, MCP-1, IFN-β, IFN-γ, TNF-α, and GM-CSF. Most of cytokines in this panel are produced by innate immune cells, linking the innate and adaptive immunity and/or bystander cells. This assay panel provides higher detection sensitivities and broader dynamic ranges than traditional ELISA methods. The panel has been validated by detecting expected changes in biological samples.

A LEGENDplex™ Mix and Match system is available to customize assays for specificities within this panel.

Product Details
View current Manual (pdf)

Kit Contents

Kit Contents
  • Setup Beads: PE Beads 
  • Setup Beads: Raw Beads 
  • Capture Beads
  • Detection Antibody 
  • Standard Cocktail, Lyophilized 
  • SA-PE 
  • Matrix C, Lyophilized 
  • Assay Buffer 
  • Wash Buffer 
  • V-bottom Plate 
  • Plate Sealers 

Product Details

Verified Reactivity
Mouse
Application

Multiplex


Learn more about LEGENDplex™ at biolegend.com/legendplex

Download the LEGENDplex™ software here.
Product Citations
  1. Chandran S, et al. 2020. Front Immunol. 11:787. PubMed
  2. Geng G, et al. 2021. Elife. 10: . PubMed
  3. Yakkala C, et al. 2021. Front Immunol. 12:695150. PubMed
  4. Bryant JD, et al. 2021. Brain Behav Immun. 97:204. PubMed
  5. Gerber JP, et al. 2021. Nat Cell Biol. 23:1224. PubMed
  6. Aguayo–Mazzucato C, et al. 2019. Cell Metab. 30:129. PubMed
  7. Chen Z, et al. 2021. Front Immunol. 12:684823. PubMed
  8. Li Y, et al. 2020. Cell Rep. 30:1753. PubMed
  9. Blackburn CMR, et al. 2021. Atherosclerosis. 330:76. PubMed
  10. Gärtner F, et al. 2021. Front Immunol. 12:745132. PubMed
  11. Rao E, et al. 2021. Sci Immunol. 6:. PubMed
  12. Gu T, et al. 2021. Front Immunol. 11:621441. PubMed
  13. Yusufu I, et al. 2021. Int J Mol Sci. 22: . PubMed
  14. Dong M, et al. 2022. Front Pharmacol. 13:1002269. PubMed
  15. Cui J, et al. 2020. Dev Cell. 55:617. PubMed
  16. Wang Y, et al. 2021. Front Immunol. 12:654463. PubMed
  17. Leblond MM, et al. 2020. Cancer Immunol Res. 8:1180. PubMed
  18. Slezak AJ, et al. 2022. ACS Cent Sci. 8:1435. PubMed
  19. Tansakul M, et al. 2020. Front Immunol. 1.222916667. PubMed
  20. Liang YC, et al. 2022. STAR Protoc. 3:101575. PubMed
  21. Lin JH, et al. 2020. J Exp Med. 217:00:00. PubMed
  22. Singh Y, et al. 2019. Front Neurosci. 1.258333333. PubMed
  23. Shipley FB, et al. 2020. Neuron. 108:623. PubMed
  24. Gihring A, et al. 2020. Front Physiol. 1.047916667. PubMed
  25. Singh Y, et al. 2020. Sci Rep. 10:16131. PubMed
  26. Farris BY, et al. 2019. Immun Inflamm Dis. 0.518055556. PubMed
  27. Luo L, et al. 2022. J Neuroinflammation. 19:141. PubMed
  28. Duan L, et al. 2021. J Inflamm Res. 14:4267. PubMed
  29. Schierer S, et al. 2018. Life Sci Alliance. 1:e201800093. PubMed
  30. Madeshiya AK, et al. 2022. Transl Psychiatry. 12:50. PubMed
  31. Luo L, et al. 2021. Mediators Inflamm. 2021:1849428. PubMed
  32. Vogel A, et al. 2022. Cell Rep. 38:110420. PubMed
  33. Alfaidi M, et al. 2020. J Clin Invest. 130:4331. PubMed
  34. Boyce M, et al. 2022. Cells. 11:. PubMed
  35. Su L, et al. 2020. Biomed Pharmacother. 131:110643. PubMed
  36. Schmit T, et al. 2022. Cell Rep. 38:110456. PubMed
  37. Oster P, et al. 2022. Gut. 71:457. PubMed
  38. Tripathi A, et al. 2021. Mol Psychiatry. 26:3043. PubMed
  39. Xu C, et al. 2022. Elife. 11:. PubMed
  40. Fotheringham AK, et al. 2021. iScience. 24:103308. PubMed
Materials Not Included
  • Flow Cytometer
  • Pipettes and Tips
  • Reagent Reservoirs for Multichannel Pipettes
  • Polypropylene Microfuge Tubes
  • Vortex Mixer
  • Sonicator
  • Plate Shaker
  • A Vacuum Filtration Unit and a Vacuum Source (if using filter plates)

Related FAQs

If I don't have a vacuum, how do I remove the liquid from my plate?

If you do not have a vacuum, the assay should be run in a V-bottom plate. After centrifugation using a swinging-bucket rotor with a plate adaptor, you can remove the liquid by flicking the plate quickly, dumping the contents into a sink, and patting it dry carefully on a stack of clean paper towels without losing the beads. Alternatively, you can remove the liquid by using a pipette.

Should I perform the assay with the filter plates or with V-bottom plates?

Filter plates or V-bottom plates have been included in some kits for your convenience. A vacuum filtration unit is required to work with the filter plates. However, if you don’t have access to a vacuum manifold or if you prefer, then you can use the V-bottom plates and follow the recommended assay protocols for the type of plates you choose. All plates should be made from low binding polypropylene. Polystyrene ELISA or cell culture plates should not be used.

After I finish the staining process, how long can I wait before reading my LEGENDplex™ samples?

The samples can be kept overnight at 4°C while being protected from exposure to light and be read the next day. There may be a decrease in signal, but overall, the assay results should not be affected. Storing the samples for extended periods of time is not recommended, as it could lead to further reductions in signal.

What is the shelf life of LEGENDplex™ kits?

LEGENDplex™ kits are guaranteed for 6 months from the date of receipt, but may have a shelf life of up to 2 years from the date of manufacture.

Is special software required for data analysis?

Typically flow cytometers generate output files in FCS format (e.g. FCS 2.0, 3.0, or 3.1) and in some cases in list mode file format (LMD). Other software may be available to analyze FCS files. Data generated using LEGENDplex™ kits can be analyzed using the freely available LEGENDplex™ data analysis software. Please check our website for the most updated versions of the software.

Go To Top Version: 4    Revision Date: 03/28/2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account