GMP PE anti-human CD10 Antibody

Pricing & Availability
Clone
HI10a (See other available formats)
Workshop
V CD10.7
Other Names
Common acute lymphoblastic leukemia antigen (CALLA), Enkephalinase, Neutral endopeptidase, Neprilysin
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
HI10a_GMP_PE_CD10_Antibody_082622
Typical results from human peripheral blood granulocytes stained either with HI10a PE used at 5 µL/test (filled histogram) or with an isotype control (open histogram).
  • HI10a_GMP_PE_CD10_Antibody_082622
    Typical results from human peripheral blood granulocytes stained either with HI10a PE used at 5 µL/test (filled histogram) or with an isotype control (open histogram).
Compare all formats See GMP PE spectral data
Cat # Size Price Save
260150 100 tests ¥62,920
Description

CD10 is a 100 kD neutral endopeptidase and a member of the metalloprotease family. It is a type II transmembrane protein also known as common acute lymphoblastic leukemia antigen (CALLA), enkephalinase, and neprilysin. CD10 is expressed on B cell precursors, T cell precursors, and neutrophils. CD10 is involved in B cell development and has been shown to bind opioid enkephalins, bradykinin, angiotensins I and II, and other biologically active peptides.

Product Details
Technical data sheet

Product Details

Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and 0.2% (w/v) BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with PE under optimal conditions.
Concentration
200 µg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
RRID
AB_2924509 (BioLegend Cat. No. 260150)
Disclaimer

GMP RUO Flow Cytometry Antibodies. BioLegend GMP RUO fluorophore conjugated antibodies are manufactured in a dedicated GMP facility and compliant with ISO 13485:2016. For research use only. Not for use in diagnostic or therapeutic procedures. Our processes include:

  • Batch-to-batch consistency
  • Material traceability
  • Documented procedures
  • Documented employee training
  • Equipment maintenance and monitoring records
  • Lot-specific certificates of analysis
  • Quality audits per ISO 13485:2016
  • QA review of released products

Antigen Details

Structure
Type II transmembrane metalloprotease family, 100 kD
Distribution

B cell precursors, T cell precursors, neutrophils

Function
Zinc-binding metalloproteinase, B cell development
Ligand/Receptor
Biologically active peptides including opioid enkephalins, bradykinin, angiotensions I & II
Cell Type
B cells, Neutrophils
Biology Area
Immunology
Molecular Family
CD Molecules
Antigen References

1. Shipp M, et al. 1993. Blood 82:1052.
2. Lu B, et al. 1995. J. Exp. Med. 181:2271.

Gene ID
4311 View all products for this Gene ID
UniProt
View information about CD10 on UniProt.org

Related FAQs

What type of PE do you use in your conjugates?
We use R-PE in our conjugates.

Other Formats

View All CD10 Reagents Request Custom Conjugation
Description Clone Applications
Purified anti-human CD10 HI10a FC,CyTOF®,IHC-F
PE anti-human CD10 HI10a FC
PE/Cyanine5 anti-human CD10 HI10a FC
FITC anti-human CD10 HI10a FC
APC anti-human CD10 HI10a FC
APC/Cyanine7 anti-human CD10 HI10a FC
PE/Cyanine7 anti-human CD10 HI10a FC
PerCP/Cyanine5.5 anti-human CD10 HI10a FC
Brilliant Violet 421™ anti-human CD10 HI10a FC
Brilliant Violet 510™ anti-human CD10 HI10a FC
Brilliant Violet 605™ anti-human CD10 HI10a FC
Purified anti-human CD10 (Maxpar® Ready) HI10a FC,CyTOF®
Brilliant Violet 711™ anti-human CD10 HI10a FC
PE/Dazzle™ 594 anti-human CD10 HI10a FC
APC/Fire™ 750 anti-human CD10 HI10a FC
APC anti-human CD10 HI10a FC
PE anti-human CD10 HI10a FC
FITC anti-human CD10 HI10a FC
TotalSeq™-A0062 anti-human CD10 HI10a PG
TotalSeq™-C0062 anti-human CD10 HI10a PG
APC/Fire™ 750 anti-human CD10 HI10a FC
TotalSeq™-B0062 anti-human CD10 HI10a PG
PE/Cyanine7 anti-human CD10 HI10a FC
PerCP/Cyanine5.5 anti-human CD10 HI10a FC
Brilliant Violet 785™ anti-human CD10 HI10a FC
TotalSeq™-D0062 anti-human CD10 HI10a PG
GMP APC anti-human CD10 HI10a FC
GMP FITC anti-human CD10 HI10a FC
GMP PE/Cyanine7 anti-human CD10 HI10a FC
GMP PE anti-human CD10 HI10a FC
PE/Dazzle™ 594 anti-human CD10 HI10a FC
GMP PerCP/Cyanine5.5 anti-human CD10 HI10a FC
Brilliant Violet 650™ anti-human CD10 HI10a FC
GMP PE/Dazzle™ 594 anti-human CD10 HI10a FC
Brilliant Violet 750™ anti-human CD10 HI10a FC
Spark YG™ 593 anti-human CD10 HI10a FC
Spark Blue™ 574 anti-human CD10 HI10a FC
Go To Top Version: 1    Revision Date: 09/19/2022

For Research Use Only. Suitable for ex vivo cell processing. Not for injection or diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account