Biotin anti-human HLA-A2 Antibody

Pricing & Availability
Clone
BB7.2 (See other available formats)
Regulatory Status
RUO
Other Names
MHC-class I
Isotype
Mouse IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
BB7point2_Biotin_HLAA2_Antibody_1_032316
Peripheral blood lymphocytes from HLA-A2 positive (top) and HLA-A2 negative (bottom) donors were stained with biotinylated anti-human HLA-A2 (clone BB7.2) (filled histograms) or biotinylated mouse IgG2b, κ isotype control (open histograms) followed by SAV-PE.
  • BB7point2_Biotin_HLAA2_Antibody_1_032316
    Peripheral blood lymphocytes from HLA-A2 positive (top) and HLA-A2 negative (bottom) donors were stained with biotinylated anti-human HLA-A2 (clone BB7.2) (filled histograms) or biotinylated mouse IgG2b, κ isotype control (open histograms) followed by SAV-PE.
  • BB7point2_Biotin_HLAA2_Antibody_2_032316
Compare all formats
Cat # Size Price Quantity Check Availability Save
343322 100 µg 186€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

HLA-A2 is most common in Northern Asia and North America populations. MHC class I antigens associated with β2-microglobulin are expressed by all human nucleated cells. MHC class I molecules are involved in presentation of antigens to CD8+ T cells, playing an important role in cell-mediated immune responses and tumor surveillance.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Papain solubilized HLA-A2
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with biotin under optimal conditions.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

The BB7.2 antibody recognizes human leukocyte antigen (HLA) A2 which is a subset of MHC-class I molecules encoded by A*02 alleles.

Additional reported applications (for the relevant formats) include: immunoprecipitation3.

Application References
  1. Brodsky FM, et al. 1979. Immunol. Rev. 47:3.
  2. Parham P and Brodsky FM. et al. 1981. Hum. Immunol. 3:277.
  3. Lubben NB, et al. 2007. Mol Biol Cell. 18:3351. (IP)
Product Citations
  1. Macedo C, et al. 2021. Am J Transplant. 21:2372. PubMed
  2. Liu X, et al. 2020. Nature. . PubMed
RRID
AB_2572191 (BioLegend Cat. No. 343322)

Antigen Details

Structure
Ig superfamily
Distribution

A*02 individuals leukocytes

Function
Antigen presentation
Ligand/Receptor
CD8, CD3/TCR
Cell Type
Leukocytes
Biology Area
Immunology
Molecular Family
MHC Antigens
Gene ID
3105 View all products for this Gene ID
UniProt
View information about HLA-A2 on UniProt.org

Related FAQs

How many biotin molecules are per antibody structure?
We don't routinely measure the number of biotins with our antibody products but the number of biotin molecules range from 3-6 molecules per antibody.
Go To Top Version: 1    Revision Date: 03/24/2016

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.