Product: Brilliant Violet 711™ anti-human CD14
Catalog No.: 301838
Anne Rissiek, Dr. Universitätsklinikum Hamburg-Eppendorf (UKE)

Anti-human CD14 Brilliant Violet 711™
Overall: Product Quality: Ease of Use:
Good discrimination of monocytes in human whole blood.
Experimental Design

Application: Flow Cytometry
Cells used: Human EDTA blood
Brief Protocol: 1. 100 µl EDTA blood plus 50 µl antibody cocktail (in FACS Buffer), incubate for 30 min at RT.
2. Lyse red good cells by adding 1 ml Lysis Buffer, incubate for 10 min at RT, wash 2x with PBS, 400 g, 5 min, trash supernatant.
3. Resuspend cells in 200-300 µl FACS Buffer, FACS analysis
The CD14 antibody was titrated and applied at a final dilution of 1:300.
Results Summary: Good discrimination of monocytes in human whole blood.
Additional Notes: Gating strategy: Lymphocytes --> Single cells --> CD45+ --> CD14+.
Data Image

Click on the image for full size data.
Publication Status

This data has not been published.