Biotin anti-human CD274 (B7-H1, PD-L1) Antibody

Pricing & Availability
Clone
29E.2A3 (See other available formats)
Regulatory Status
RUO
Other Names
Programmed cell death ligand 1 (PD-L1), B7 homolog 1 (B7-H1)
Isotype
Mouse IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
29Edot2A3_Biotin_022508
Human peripheral blood lymphocytes stained with biotinylated 29E.2A3, followed by Sav-PE
  • 29Edot2A3_Biotin_022508
    Human peripheral blood lymphocytes stained with biotinylated 29E.2A3, followed by Sav-PE
Cat # Size Price Quantity Check Availability Save
329703 25 µg 80,00 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
329704 100 µg 180,00 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD274, also known as PD-L1 and B7-H1, is type I transmembrane glycoprotein that serves as a ligand for CD279 (PD-1). This interaction is believed to regulate the balance between the stimulatory and inhibitory signals needed for responses to microbes and maintenance of self-tolerance. CD274 is involved in the costimulation of T cell proliferation and IL-10 and IFN-γ production in an IL-2-dependent and CD279-independent manner. Conflicting data has shown that CD274 can inhibit T cell proliferation and cytokine production, and alternatively, enhance T cell activation. Other studies suggest that CD274 may signal bidirectionally, raising interesting implications for its expression in a wide variety of cell types, including T and B cells, antigen-presenting cells, and nonhematopoietic cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Reactivity
Human, African Green, Baboon, Cynomolgus, Rhesus
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Full length human PD-L1
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography, and conjugated with biotin under optimal conditions.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. Do not freeze.
Application

FC - Quality tested

Recommended Usage
Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤2.0 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.
Application Notes

Clone 29E.2A3 is reported to recognize an epitope on PD-L1 within the PD-L1-CD80 binding region5. Additional reported applications (for the relevant formats) include: blocking1-3 and immunohistochemical staining of acetone-fixed frozen sections1. The Ultra-LEAF™ purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. No. 329715, 329716, 329745 - 329748). 

It has been observed that clone 29E.2A3 is able to bind to Alexa Fluor® 700 antibody conjugates during multi-color immunofluorescent staining. This interaction can be resolved by sequentially staining with the 29E.2A3 antibody first and then followed by the Alexa Fluor® 700 conjugate of interest.

Clone 29E.2A3 does not work in Western blot applications7.

Application References

(PubMed link indicates BioLegend citation)
  1. Brown J, et al. 2003. J. Immunol. 170:1257. (FC, IHC, Block)
  2. Radziewicz H, et al. 2007. J. Virol. 81:2545. (Block)
  3. Nakamoto N, et al. 2009. PLoS Pathog. 5:e1000313. (Block)
  4. Barsoum IB, et al. 2014. Cancer Res. 74:665. PubMed
  5. Haile, S et al. 2013. J. Immunol. 191:2829.
  6. RL M, et al. 2015. PNAS. 112:6506-6514. PubMed
  7. Mahoney KM, et al. 2015. Cancer Immunol. Res. 3:1308.
Product Citations
  1. Hassounah NB, et al. 2019. Cancer Immunol Immunother. 68:407. PubMed
RRID
AB_940362 (BioLegend Cat. No. 329703)
AB_940364 (BioLegend Cat. No. 329704)

Antigen Details

Distribution

T cells, B cells, NK cells, monocytes/macrophages, granulocytes and dendritic cells

Function
CD274 is involved in the costimulatory signal, essential for T lymphocyte proliferation and production of IL-10 and IFN-γ, in an IL-2-dependent and a PD-1-CD1-independent manner. Its interaction with PD-1-CD1 inhibits T-cell proliferation and cytokine production.
Ligand/Receptor
PD-1 (PDCD1)
Cell Type
B cells, Dendritic cells, Fibroblasts, Granulocytes, Macrophages, Monocytes, NK cells, T cells
Biology Area
Cancer Biomarkers, Costimulatory Molecules, Immunology
Molecular Family
Adhesion Molecules, CD Molecules, Immune Checkpoint Receptors
Antigen References

1. Sharpe A, et al. 2007. Nat. Immunol. 8:239.

Gene ID
29126 View all products for this Gene ID
UniProt
View information about CD274 on UniProt.org

Related FAQs

How many biotin molecules are per antibody structure?
We don't routinely measure the number of biotins with our antibody products but the number of biotin molecules range from 3-6 molecules per antibody.
Go To Top Version: 6    Revision Date: 11.30.2016

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere
Insert Note Here
Save Close Clear
Lab Timer
Tools
Login / Register
Remember me
Forgot your password? Reset password?
Create an Account