PE anti-human CD11b Recombinant Antibody

Pricing & Availability
Clone
QA20A58 (See other available formats)
Regulatory Status
RUO
Other Names
alpha-chain of C3bi receptor, alphaM, C3bi receptor, CD11b, gp155/95, integrin a, M-chain, Mac-1
Isotype
Mouse IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
QA20A58_PE_CD11b_Antibody_2_021722
Human peripheral blood monocytes were stained with anti-human CD11b (clone QA20A58) PE (filled histogram) or mouse IgG2a, κ PE isotype control (open histogram).
  • QA20A58_PE_CD11b_Antibody_2_021722
    Human peripheral blood monocytes were stained with anti-human CD11b (clone QA20A58) PE (filled histogram) or mouse IgG2a, κ PE isotype control (open histogram).
Compare all formats See PE spectral data
Cat # Size Price Quantity Check Availability Save
379903 25 tests $86
Check Availability


Need larger quantities of this item?
Request Bulk Quote
379904 100 tests $280
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD11b (integrin alpha M subunit) is a type I transmembrane glycoprotein. CD11b combines with the Integrin beta 2 subunit (CD18) to form the non-covalent heterodimer Integrin alpha M/beta 2, also known as Mac-1 and complement receptor type 3 (CR3). Mac-1 plays an important role in cell-cell interaction by binding its ligands ICAM-1 (CD54), ICAM-2 (CD102), ICAM-4 (CD242), iC3b, and fibrinogen. CD11b is primarily expressed on granulocytes, monocytes/macrophages, dendritic cells, NK cells, and subsets of T and B cells.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Antibody Type
Recombinant
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with PE under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

Excitation Laser
Blue Laser (488 nm)
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application Notes

The binding of clone QA20A58 can be completely blocked by reference clone.

Other anti-hCD11b clone ICRF44 does not affect the binding of clone QA20A58 to target.

RRID
AB_2910449 (BioLegend Cat. No. 379903)
AB_2910449 (BioLegend Cat. No. 379904)

Antigen Details

Structure
Integrin family, associates with integrin β2 (CD18), 170 kD
Distribution

Granulocytes, monocytes/macrophages, dendritic cells, NK cells, subsets of T and B cells

Function
Adhesion, chemotaxis, phagocytosis, neutrophil activation
Ligand/Receptor
ICAM-1 (CD54), ICAM-2 (CD102), ICAM-4 (CD242), iC3b, fibrinogen
Cell Type
B cells, Dendritic cells, Granulocytes, Neutrophils, NK cells, T cells, Tregs
Biology Area
Cell Adhesion, Cell Biology, Immunology, Innate Immunity
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References
  1. Barclay A, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
  2. Springer TA. 1994. Cell. 76:301-14.
  3. Coxon A, et al. 1996. Immunity. 5:653-66.
Gene ID
3684 View all products for this Gene ID
UniProt
View information about CD11b on UniProt.org

Related FAQs

What type of PE do you use in your conjugates?
We use R-PE in our conjugates.
Go To Top Version: 1    Revision Date: 02/17/2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account