LEGENDplex™ HU Essential Immune Response Panel Detection Abs

Pricing & Availability
Other Names
Human Essential Immune Response Panel Detection Antibodies
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
740931 100 tests (3.5 mL) $250
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

The LEGENDplex™ Human Essential Immune Response Panel Detection Antibodies contains 13 anti-human antibodies against IL-4, IL-2, CXCL10 (IP-10), IL-1β, TNF-α, CCL2 (MCP-1), IL-17A, IL-6, IL-10, IFN-γ, IL-12p70, CXCL8 (IL-8), Free Active TGF-β1. This Detection cocktail is recommended for use with the following in Mix and Match assays:

Human Essential Immune Response Panel

740932 LEGENDplex™ Human Essential Immune Response Panel Standard
740933 LEGENDplex™ Human IL-4 Capture Bead A4, 13X
740934 LEGENDplex™ Human IL-2 Capture Bead A5, 13X
740935 LEGENDplex™ Human CXCL10 (IP-10) Capture Bead A6, 13X
740936 LEGENDplex™ Human IL-1β Capture Bead A7, 13X
740937 LEGENDplex™ Human TNF-α Capture Bead A8, 13X
740938 LEGENDplex™ Human CCL2 (MCP-1) Capture Bead A10, 13X
740939 LEGENDplex™ Human IL-17A Capture Bead B2, 13X
740940 LEGENDplex™ Human IL-6 Capture Bead B3, 13X
740941 LEGENDplex™ Human IL-10 Capture Bead B4, 13X
740942 LEGENDplex™ Human IFN-γ Capture Bead B5, 13X
740943 LEGENDplex™ Human IL-12p70 Capture Bead B6, 13X
740904 LEGENDplex™ Human CXCL8 (IL-8) Capture Bead B7, 13X
740944 LEGENDplex™ Human Free Active TGF-β1 Capture Bead B9, 13X
740368 LEGENDplex™ Buffer Set A
740377 LEGENDplex™ Filter Plate
OR
740379 LEGENDplex™ V-Bottom Plate

Product Details
View Current Manual (pdf)

Product Details

Reactivity
Human
Application

Multiplex


Learn more about LEGENDplex™ at biolegend.com/legendplex

Download the LEGENDplex™ software here.

Antigen Details

Biology Area
Immunology
Molecular Family
Cytokines/Chemokines
Gene ID
NA

Related FAQs

After I finish the staining process, how long can I wait before reading my LEGENDplex™ samples?

The samples can be kept overnight at 4°C while being protected from exposure to light and be read the next day. There may be a decrease in signal, but overall, the assay results should not be affected. Storing the samples for extended periods of time is not recommended, as it could lead to further reductions in signal.

If I don't have a vacuum, how do I remove the liquid from my plate?

Do NOT invert the plate to dump the liquid. The beads will not adhere to the plate. After centrifugation using a swing bucket rotor with a plate adaptor, you can remove the liquid by using a pipette.

Is special software required for data analysis?

Typically flow cytometers generate output files in FCS format (e.g. FCS 2.0, 3.0, or 3.1) and in some cases in list mode file format (LMD). FCS files can be analyzed by different software. Data generated from using LEGENDplex™ kits can be analyzed using the LEGENDplex™ data analysis software freely available on the BioLegend website (biolegend.com/legendplex/software). A free of charge software license dongle is currently provided in the kit. Please check our website for the most updated versions of the software.

Should I perform the assay with the filter plates or with V-bottom plates?

Filter plates or V-bottom plates have been included in some kits for your convenience. Performing the assay with filter plates is generally recommended. A vacuum filtration unit is required to work with the filter plates. If however, you don’t have access to a vacuum manifold, then you can use the V-bottom plates or micro-FACS tubes as described in the manual and follow the recommended assay protocols for the type of plates or tubes you choose. All tubes and plates should be made from low binding polypropylene. Polystyrene ELISA or cell culture plates should not be used.

What is the shelf life of LEGENDplex™ kits?

LEGENDplex™ kits are valid for 6 months from the date of receipt. 

Go To Top Version: 1    Revision Date: 01/23/2019

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

Login/Register
Forgot your password? Reset Password
Request an Account