APC/Fire™ 750 anti-human CD22 Antibody

Pricing & Availability
Clone
S-HCL-1 (See other available formats)
Regulatory Status
RUO
Other Names
BL-CAM, Siglec-2, Lyb8
Isotype
Mouse IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
S-HCL-1_APCFire750_CD22_Antibody_1_022420
Human peripheral blood lymphocytes were stained with CD19 PE and CD22 (clone S-HCL-1) APC/Fire™ 750 (left) or mouse IgG2b, κ APC/Fire™ 750 isotype control (right).
  • S-HCL-1_APCFire750_CD22_Antibody_1_022420
    Human peripheral blood lymphocytes were stained with CD19 PE and CD22 (clone S-HCL-1) APC/Fire™ 750 (left) or mouse IgG2b, κ APC/Fire™ 750 isotype control (right).
Compare all formats See APC/Fire™ 750 spectral data
Cat # Size Price Quantity Check Availability Save
363521 25 tests $176
Check Availability


Need larger quantities of this item?
Request Bulk Quote
363522 100 tests $276
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD22 is a 130 kD type I transmembrane glycoprotein also known as Siglec-2 and BL-CAM and is a member of the immunoglobulin superfamily (sialoadhesion subgroup). CD22 is expressed in the cytoplasm of pro-B and pre-B cells, and on the surface of mature B and activated B cells, but not on plasma cells. CD22 is present in the B cell receptor complex and associates with SHP-1, Syk, Lck, Lyn, and phospholipase Cγ1. A primary function of CD22 is thought to be in limiting antigen receptor signaling by modulating B cell activation threshold. CD22 has been shown to bind to CD45RO and CD75, although the natural ligands for this molecule remain controversial.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA)
Preparation
The antibody was purified by affinity chromatography and conjugated with APC/Fire™ 750 under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood. It is recommended that the reagent be titrated for optimal performance for each application.

* APC/Fire™ 750 has a maximum excitation of 650 nm and a maximum emission of 774 nm.

Excitation Laser
Red Laser (633 nm)
Application Notes
  1. Nitschke L. 2005. Curr. Opin. Immunol. 17:290
  2. Foon Ka, et al. 1986. Blood. 68:297
  3. Schwarting R, et al. 1985. Blood. 65:974
  4. Campana D, et al. 1985. J. Immunol. 134:1524
RRID
AB_2832720 (BioLegend Cat. No. 363521)
AB_2832721 (BioLegend Cat. No. 363522)

Antigen Details

Structure
Ig superfamily, a type I glycosylated integral transmembrane protein, 120-130 kD
Distribution

B cells

Function
Adhesion, B-monocyte and B-T interactions
Ligand/Receptor
CD45RO, CD75
Cell Type
B cells
Biology Area
Immunology
Molecular Family
CD Molecules, Siglec Molecules
Antigen References
  1. Clark E. 1993. J. Immunol. 150:4715.
  2. Shan D, et al. 1995. J. Immunol. 154:4466.
Gene ID
933 View all products for this Gene ID
UniProt
View information about CD22 on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 1    Revision Date: 02/24/2020

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account