LEGEND MAX™ Mouse MCP-1 ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
Monocyte chemoattractant protein-1 (MCP1), Monocyte chemoattractant and activating factor (MCAF), JE, Small inducible cytokine A2 (SCYA2), HC-11 (HC11), P6, Smooth muscle cell chemotactic factor (SMC-CF, SMCCF), CCL2, MCP-1 Precoated ELISA Kit
Ave. Rating
Submit a Review
Product Citations
publications
Mouse_MCP-1_ELISA_1_101118
Representative LEGEND MAX™ Mouse MCP-1 standard curve.
  • Mouse_MCP-1_ELISA_1_101118
    Representative LEGEND MAX™ Mouse MCP-1 standard curve.
  • Mouse_MCP-1_ELISA_2_101118
    Pooled serum and plasma samples from 4 different mouse strains were quantified using the LEGEND MAX™ Mouse MCP-1 ELISA Kit.
Cat # Size Price Quantity Check Availability Save
446207 1 Pre-coated Plate $462
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Mouse MCP-1, also known as CCL2, is a member of the CC chemokine family. It is widely expressed in endothelial cells, smooth muscle cells and monocytes in response to several atherogenic stimulants such as CD40 ligand, platelet derived growth factor (PDGF), interleukin-1β (IL-1β) and oxidized low density lipoprotein. Several recent in vivo studies have disclosed critical roles of MCP-1 in atherosclerosis. In addition, MCP-1 has been implicated in monocytic infiltration of tissues during several inflammatory diseases, and has been implicated in macrophage-mediated tumor growth suppression in mice. MCP-1 has been shown to have direct effects on tumor cells in an autocrine and paracrine fashion in multiple cancers, including breast, lung, cervical, ovarian, and prostatic. In addition, MCP-1 plays a key role in the regulation of MMPs during transmigration.

MCP-1 has been described as a new diagnostic marker and therapeutic target for progressive renal injury in diabetic nephropathy. Kidney epithelial cells, including glomerular podocytes and tubular cells make MCP-1 in response to high glucose and advanced glycation end products. MCP-1 promotes inflammation and progressive injury in diabetic kidneys.

The BioLegend LEGEND MAX™ Mouse MCP-1 ELISA Kit is a Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is precoated with a hamster monoclonal anti-mouse/human/rat MCP-1 antibody. The detection antibody is a biotinylated goat polyclonal anti-mouse MCP-1 antibody. This kit is specifically designed for the accurate quantitation of mouse MCP-1 from cell culture supernatant, serum, plasma, and other biological fluids. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical data sheet

Kit Contents

Kit Contents
  • Anti-Mouse MCP-1 Pre-coated 96-well Strip Microplate
  • Mouse MCP-1 Dectection Antibody
  • Mouse MCP-1 Standard
  • Avidin-HRP
  • Assay Buffer A
  • Wash Buffer (20X)
  • Substrate Solution F
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Mouse
Application

ELISA

Sensitivity
1.33 pg/mL
Standard Range
7.8-500 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1,000 µL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Biology Area
Immunology, Neuroinflammation, Neuroscience
Molecular Family
Cytokines/Chemokines
Gene ID
20296 View all products for this Gene ID
UniProt
View information about MCP-1 on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 1    Revision Date: 02/05/2018

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account