Product: Brilliant Violet 510™ Streptavidin
Catalog No.: 405233
Andreia Lino, PhD Deutsches Rheuma-Forschungszentrum, a Leibniz Institute

Brilliant Violet 510™ Streptavidin for Flow Cytometry
Overall: Product Quality: Ease of Use:
Good, reliable not so bright option.
Experimental Design

Application: Flow cytometry
Cells used: Mouse splenocytes
Brief Protocol: Resuspend in PBS/BSA and count the cells. Load up to 5x106 cells onto a V-Bottom 96-well-plate. Spin down, resuspend in 50uL of PBS/BSA containing αFcγR (24.62) 30 µg/ml and incubate 15min at 4°C. Spin down and resuspend in 50 µl of antibody staining solution containing biotinylated antibody against the molecule to stain. Incubate 15min at 4°C in the dark. Wash with PBS/BSA, spin down and resuspend in 50 µl staining solution containing Brilliant Violet 510™ Streptavidin (1:400). Incubate 15min at 4°C in the dark. Wash with PBS/BSA, spin down resuspend and transfer to FACS tubes to read. Use PI to exclude the dead cells.
Results Summary: In this case anti-mouse CD23biot was used, around 50% of live lymphocytes should be CD23biot-SABrilliant Violet 510™+.
Additional Notes:
Data Image

Click on the image for full size data.
Publication Status

This data has not been published.