- Other Names
- Control Cells
- Ave. Rating
- Submit a Review
- Product Citations
- publications

-
Veri-Cells™ Activated (surface) PBMC stained with CD3 APC/Fire™ 750, CD4 FITC, and CD279 (PD-1) PE/Cy7 or CD366 (TIM3) PE (left). Plots were generated on CD3+ cells and gated based on corresponding isotype control stains (right). -
Veri-Cells™ Activated (surface) PBMC stained with CD3 APC/Fire™ 750, CD4 FITC, and CD25 PerCP/Cy5.5 or CD69 Alexa Fluor® 700 (left). Plots were generated on CD3+ cells and gated based on corresponding isotype control stains (right). -
Veri-Cells™ Activated (surface) PBMC stained with CD3 APC/Fire™ 750, CD4 FITC, and CD134 (OX40) APC or TIGIT (VSTM3) PE/Dazzle™ 594 (left). Plots were generated on CD3+ cells and gated based on corresponding isotype control stains (right). -
Veri-Cells™ Activated (surface) PBMC scatter profile (left) and stain for CD3 APC/Fire™ 750 (right).
Cat # | Size | Price | Quantity Avail. | Save | ||
---|---|---|---|---|---|---|
426701 | 10 tests | £65 | ||||
426703 | 50 tests | £270 |
The reconstituted lyophilized human Activated (surface) PBMC can be used for immunofluorescent staining and multi-color flow cytometry assays. The cells can be used as activated cell marker controls with minimal variability across experiments. These cells have been verified to work with commonly tested cell surface, as well as T cell activation markers such as CD3, CD4, CD8, CD25, CD366(TIM3), TIGIT, CD69, CD279 and CD134.
This product contains human cells, a potentially biohazardous material. Blood used in preparation of these samples was tested and found to be negative for antibody and nucleic acid testing against Human Immunodeficiency virus (HIV), Hepatitis B and C virus and HTLV (Human T-Lymphotrophic virus I and II), surface antigen for Hepatitis B (HBsAg) virus and syphilis and West Nile Virus using FDA approved methods. Biological tests are not 100% accurate. Use standard precautions when handling, and treat as if the product is capable of transmitting disease. When handling or disposing, follow precautions described in CDC and FDA recommendations and OSHA Bloodborne Pathogen guidelines.
Kit Contents
- Kit Contents
-
Cat. No. 426701
- 2 vials of Veri-Cell™ Activated (surface) PBMC (≥1 X 106 cells per vial)
- 1 vials of 0.7 ml Veri-Cells™ Buffer A
Cat. No. 426703
- 10 vials of Veri-Cell™ Activated (surface) PBMC (≥1 X 106 cells/vial)
- 5 vials of 0.7 ml Veri-Cells™ Buffer A
Product Details
- Formulation
- Cat. No. 426701: 2 vials each containing ≥1 X 106 lyophilized human peripheral blood mononuclear cells (PBMC).Cat. No. 426703: 10 vials each containing ≥1 X 106 lyophilized human peripheral blood mononuclear cells (PBMC).
- Preparation
- The Veri-Cells™ PBMC Kit is prepared from 2 lyophilized human Activated (surface) PBMC and a vial of Veri-Cells™ Buffer A. Veri-Cells Activated (surface) PBMC contain lyophilized PBMCs that had been stimulated using Concanavalin A (ConA) for 72 hours.
- Storage & Handling
- Store the kit at 2°C - 8°C upon receipt. Do not open sealed pouch until ready to use. Once reconstituted, the cells may be used for up to five days if properly stored at 2°C - 8°C in the buffer provided. Contact BioLegend Technical Support for information on the current lots
- Application
-
FC - Quality tested
- Recommended Usage
-
50 µl per test (after reconstitution with 325 µl of Veri-Cells™ Buffer A)
Note: Veri-Cells™ Buffer A may show precipitation over time, however this is normal and does not affect performance of the buffer. - Application Notes
-
The Veri-Cells™ Activated (surface) PBMC Kit can be used as a positive control for detecting T cell activation markers such as CD25, CD69, CD134, CD279, CD366 (TIM3) and TIGIT (VSTM3). Assessing the suitability of using this product as a control for end user’s molecule of interest is recommended, as each lot is verified based on the expression levels of markers mentioned above. For best results, Cell Staining Buffer is recommended for any washing steps. Product performance specifications are based on testing with BioLegend reagents and protocols. Deviations from the use of these reagents and procedures have not been assessed and may affect performance.
Antibodies Used for Product Validation
Target
Clone
Fluorophore
CD3
SK7
APC/Fire™ 750
CD4
RPA-T4
FITC
CD25
M-A251
PerCP/Cyanine5.5
CD366/TIM3
F38-2E2
PE
TIGIT
A15153G
PE/Dazzle™ 594
CD69
FN50
Alexa Fluor® 700
CD279
EH12.2H7
PE/Cy7
CD134
Ber-ACT35
APC
Please use our CoA Look-Up Tool to find the expected lot-specific frequencies of certain cell populations included within each lot of Veri-Cells™ Activated (Surface) PBMC.
Antigen Details
- Biology Area
- Immunology
- Molecular Family
- CD Molecules
- Gene ID
- NA