Ultra-LEAF™ Purified anti-mouse CD223 (LAG-3) Recombinant Antibody

Pricing & Availability
Clone
QA20A93 (See other available formats)
Regulatory Status
RUO
Other Names
CD223, LAG-3, LAG3, lymphocyte-activation gene-3
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
QA20A93_ULEAF_CD223_Antibody_030322
ConA+ IL-2 stimulated (3 days) C57BL/6 splenocytes stained with Ultra-LEAF™ purified anti-mouse CD223 (LAG-3) recombinant (clone QA20A93) (filled histogram) or purified mouse IgG1, κ isotype control (open histogram) followed by PE anti-mouse IgG1.
  • QA20A93_ULEAF_CD223_Antibody_030322
    ConA+ IL-2 stimulated (3 days) C57BL/6 splenocytes stained with Ultra-LEAF™ purified anti-mouse CD223 (LAG-3) recombinant (clone QA20A93) (filled histogram) or purified mouse IgG1, κ isotype control (open histogram) followed by PE anti-mouse IgG1.
Cat # Size Price Quantity Check Availability Save
109703 100 µg £76
Check Availability


Need larger quantities of this item?
Request Bulk Quote
109704 1 mg £102
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD223, also known as LAG-3, is 70 kD type I transmembrane glycoprotein within the Ig superfamily. It is the gene product of lymphocyte activation gene-3 with structural similarity to CD4. CD223 is expressed on activated T cells and NK cells, as well as T regulatory cells. CD223, like CD4, binds MHC class II molecules, but with higher affinity than CD4. In association with the CD3 complex, CD223 has been shown as a negative regulatory molecule to inhibit TCR-mediated signaling and regulate homeostatic T cell expansion.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Recombinant
Host Species
Mouse
Formulation
0.2 µm filtered in phosphate-buffered solution, pH 7.2, containing no preservative.
Endotoxin Level
Less than 0.01 EU/µg of the protein (< 0.001 ng/µg of the protein) as determined by the LAL test.
Preparation
The Ultra-LEAF™ (Low Endotoxin, Azide-Free) antibody was purified by affinity chromatography.
Concentration
The antibody is bottled at the concentration indicated on the vial, typically between 2 mg/mL and 3 mg/mL. To obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. This Ultra-LEAF™ solution contains no preservative; handle under aseptic conditions.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application Notes

Clone QA20A93 is able to completely block the staining of clone C9B7W on target cells.

RRID
AB_2910284 (BioLegend Cat. No. 109703)
AB_2910284 (BioLegend Cat. No. 109704)

Antigen Details

Structure
Ig superfamily
Distribution

T cells and NK cells, as well as T regulatory cells

Antigen References
  1. Baixeras E, et al. 1992. J Exp Med. 176:327-37.
Gene ID
16768 View all products for this Gene ID
UniProt
View information about CD223 on UniProt.org

Related FAQs

Do you guarantee that your antibodies are totally pathogen free?

BioLegend does not test for pathogens in-house aside from the GoInVivo™ product line. However, upon request, this can be tested on a custom basis with an outside, independent laboratory.

Does BioLegend test each Ultra-LEAF™ antibody by functional assay?

No, BioLegend does not test Ultra-LEAF™ antibodies by functional assays unless otherwise indicated. Due to the possible complexities and variations of uses of biofunctional antibodies in different assays and because of the large product portfolio, BioLegend does not currently perform functional assays as a routine QC for the antibodies. However, we do provide references in which the antibodies were used for functional assays and we do perform QC to verify the specificity and quality of the antibody based on our strict specification criteria.

Does BioLegend test each Ultra-LEAF™ antibody for potential pathogens?

No, BioLegend does not test for pathogens in-house unless otherwise indicated.  However, we can recommend an outside vendor to perform this testing as needed.

Have you tested this Ultra-LEAF™ antibody for in vivo or in vitro applications?

We don't test our antibodies for in vivo or in vitro applications unless otherwise indicated. Depending on the product, the TDS may describe literature supporting usage of a particular product for bioassay. It may be best to further consult the literature to find clone specific information.

Go To Top Version: 1    Revision Date: 03/14/2022

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account