LEGENDplex™ Human Inflammation Panel 2 Standard

Pricing & Availability
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price  
740778 1 vial £34
Check Availability


Need larger quantities of this item?
Request Bulk Quote
To purchase, view our LEGENDplex™ Mix and Match page
Description

The LEGENDplex™ Human Inflammation Panel 2 Standard contains 13 human proteins, including TGF-b1, PAI-1, sTREM-1, PTX3, sCD40L, sCD25 (IL-2Ra), CXCL12 (SDF-1), sST2, sTNF-RI, sTNF-RII, sRAGE, CX3CL1 (Fractalkine), sCD130 (gp130). This standard cocktail is intended for use with the following in Mix and Match assays:

Human Inflammation Panel 2

740777 LEGENDplex™ Human Inflammation Panel 2 Detection Antibodies
740779 LEGENDplex™ Human Free Active TGF-b1 Capture Bead A4, 13X
740780 LEGENDplex™ Human PAI-1 Capture Bead A5, 13X
740781 LEGENDplex™ Human sTREM-1 Capture Bead A6, 13X
740782 LEGENDplex™ Human PTX3 Capture Bead A7, 13X
740783 LEGENDplex™ Human sCD40L Capture Bead A8, 13X
740784 LEGENDplex™ Human sCD25 (IL-2Ra) Capture Bead A10, 13X
740785 LEGENDplex™ Human CXCL12 (SDF-1) Capture Bead B2, 13X
740786 LEGENDplex™ Human sST2 Capture Bead B3, 13X
740787 LEGENDplex™ Human sTNF-RI Capture Bead B4, 13X
740788 LEGENDplex™ Human sTNF-RII Capture Bead B5, 13X
740789 LEGENDplex™ Human sRAGE Capture Bead B6, 13X
740790 LEGENDplex™ Human CX3CL1 (Fractalkine) Capture Bead B7, 13X
740791 LEGENDplex™ Human sCD130 (gp130) Capture Bead B9, 13X
740620 LEGENDplex™ Buffer Set H
740377 LEGENDplex™ Filter Plate
OR
740379 LEGENDplex™ V-Bottom Plate

Product Details
View Current Manual (pdf)

Product Details

Reactivity
Human
Antibody Type
Monoclonal
Application

Multiplex


Learn more about LEGENDplex™ at biolegend.com/legendplex.

Download the LEGENDplex™ software here.

Antigen Details

Biology Area
Cell Biology, Neuroinflammation, Neuroscience, Innate Immunity
Molecular Family
Cytokines/Chemokines
Gene ID
NA

Related FAQs

After I finish the staining process, how long can I wait before reading my LEGENDplex™ samples?

The samples can be kept overnight at 4°C while being protected from exposure to light and be read the next day. There may be a decrease in signal, but overall, the assay results should not be affected. Storing the samples for extended periods of time is not recommended, as it could lead to further reductions in signal.

If I don't have a vacuum, how do I remove the liquid from my plate?

Do NOT invert the plate to dump the liquid. The beads will not adhere to the plate. After centrifugation using a swing bucket rotor with a plate adaptor, you can remove the liquid by using a pipette.

Is special software required for data analysis?

Typically flow cytometers generate output files in FCS format (e.g. FCS 2.0, 3.0, or 3.1) and in some cases in list mode file format (LMD). FCS files can be analyzed by different software. Data generated from using LEGENDplex™ kits can be analyzed using the LEGENDplex™ data analysis software freely available on the BioLegend website (biolegend.com/legendplex/software). A free of charge software license dongle is currently provided in the kit. Please check our website for the most updated versions of the software.

Should I perform the assay with the filter plates or with V-bottom plates?

Filter plates or V-bottom plates have been included in some kits for your convenience. Performing the assay with filter plates is generally recommended. A vacuum filtration unit is required to work with the filter plates. If however, you don’t have access to a vacuum manifold, then you can use the V-bottom plates or micro-FACS tubes as described in the manual and follow the recommended assay protocols for the type of plates or tubes you choose. All tubes and plates should be made from low binding polypropylene. Polystyrene ELISA or cell culture plates should not be used.

What is the shelf life of LEGENDplex™ kits?

LEGENDplex™ kits are valid for 6 months from the date of receipt. 

Go To Top Version: 1    Revision Date: 10/29/2018

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 9727 Pacific Heights Blvd, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

Login / Register
Forgot your password? Reset password?
Create an Account