Product: APC anti-mouse/human CD11b |
Catalog No.: 101212 |
BAOBING ZHAO, POST-DOC NORTHWESTERN UNIVERSITY |
Stain for Granulocytes Detection in Mouse Bone Marrow (APC anti-mouse/human CD11b) | |||
Overall: | Product Quality: | Ease of Use: | |
It worked well for matured granulocytes distinction. |
Experimental Design |
Application: | Flow cytometry |
Cells used: | Mouse bone marrow |
Brief Protocol: | Total bone marrow cells were stained with FITC-Gr1 (1:200) and APC-CD11b(1:200) for 20 minutes at room temperature. After wash with PBS, the cells were suspended in 300 ul PBS with PI to exclude dead cells. |
Results Summary: | It worked well for distinguishing granulocytes and other lineage cells in the bone marrow. |
Additional Notes: |
|
|
See all Reviews |