Ultra-LEAF™ Purified anti-human NKp80 Antibody

Pricing & Availability
Clone
5D12 (See other available formats)
Regulatory Status
RUO
Other Names
KLRF1, killer cell lectin-like receptor subfamily F, member 1
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Check Availability Save
346711 100 µg 216€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
346712 1 mg 595€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

NKp80, also known as killer cell lectin-like receptor subfamily F, member 1 (KLRF1), is a type II transmembrane C-type lectin-like receptor. NKp80 is expressed on the cell surface of nearly all NK cells as a homodimer with approximately 80 kD molecular mass. It is also found on a subset of effector memory CD8 T cells and γ/δ T cells. NKp80 induces NK-cell mediated cytotoxicity and cytokine production through interaction with its ligand, AICL (activation-induced C-type lectin), which is selectively expressed on myeloid cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
African Green, Baboon, Cynomolgus, Rhesus
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Recombinant ectodomain of human NKp80
Formulation
0.2 µm filtered in phosphate-buffered solution, pH 7.2, containing no preservative.
Endotoxin Level
Less than 0.01 EU/µg of the protein (< 0.001 ng/µg of the protein) as determined by the LAL test.
Preparation
The Ultra-LEAF™ (Low Endotoxin, Azide-Free) antibody was purified by affinity chromatography.
Concentration
The antibody is bottled at the concentration indicated on the vial, typically between 2 mg/mL and 3 mg/mL. Older lots may have also been bottled at 1 mg/mL. To obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. This Ultra-LEAF™ solution contains no preservative; handle under aseptic conditions.
Application

FC - Quality tested
IP, Block - Reported in the literature, not verified in house

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µL volume. It is recommended that the reagent be titrated for optimal performance for each application.

Application References

(PubMed link indicates BioLegend citation)
  1. Welte S, et al. 2006. Nat. Immunol. 7:1334.
  2. Kuttruff S, et al. 2009. Blood 113:358.
RRID
AB_2860905 (BioLegend Cat. No. 346711)
AB_2860906 (BioLegend Cat. No. 346712)

Antigen Details

Structure
Type II transmembrane c-type lectin-like receptor, homodimer, 80 kD
Distribution

NK cells, subset of CD8 T and γ/δ T cells

Ligand/Receptor
AICL (activation-induced C-type letcin)
Bioactivity
induce NK cell-mediated cytolysis and cytokine release
Cell Type
NK cells, T cells
Biology Area
Costimulatory Molecules, Immunology, Innate Immunity
Antigen References

1. Kuttruff S, et al. 2009. Blood 113:358
2. Vitale M, et al. 2001. Eur. J. Immunol. 31:233

Gene ID
51348 View all products for this Gene ID
UniProt
View information about NKp80 on UniProt.org

Related FAQs

Do you guarantee that your antibodies are totally pathogen free?

BioLegend does not test for pathogens in-house aside from the GoInVivo™ product line. However, upon request, this can be tested on a custom basis with an outside, independent laboratory.

Does BioLegend test each Ultra-LEAF™ antibody by functional assay?

No, BioLegend does not test Ultra-LEAF™ antibodies by functional assays unless otherwise indicated. Due to the possible complexities and variations of uses of biofunctional antibodies in different assays and because of the large product portfolio, BioLegend does not currently perform functional assays as a routine QC for the antibodies. However, we do provide references in which the antibodies were used for functional assays and we do perform QC to verify the specificity and quality of the antibody based on our strict specification criteria.

Does BioLegend test each Ultra-LEAF™ antibody for potential pathogens?

No, BioLegend does not test for pathogens in-house unless otherwise indicated.  However, we can recommend an outside vendor to perform this testing as needed.

Have you tested this Ultra-LEAF™ antibody for in vivo or in vitro applications?

We don't test our antibodies for in vivo or in vitro applications unless otherwise indicated. Depending on the product, the TDS may describe literature supporting usage of a particular product for bioassay. It may be best to further consult the literature to find clone specific information.

Go To Top Version: 1    Revision Date: 03.24.2020

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account