Recombinant Human E-Selectin (CD62E)-Fc Chimeric (carrier-free)

Pricing & Availability
Other Names
SELE, CD62 antigen-like family member E (CD62E), Endothelial leukocyte adhesion molecule 1 (ELAM-1), Leukocyte-endothelial cell adhesion molecule 2 (LECAM2)
Ave. Rating
Submit a Review
Product Citations
publications
Human_ESelectin_CD62E_FC_Chimeric_CF_RECOM_021017
Immobilized recombinant human E-Selectin induces adhesion of U937 cells in a dose dependent manner. ED50 for this effect is 15 - 60 ng/mL. Calcein-AM was used to measure the number of adherent cells.
  • Human_ESelectin_CD62E_FC_Chimeric_CF_RECOM_021017
    Immobilized recombinant human E-Selectin induces adhesion of U937 cells in a dose dependent manner. ED50 for this effect is 15 - 60 ng/mL. Calcein-AM was used to measure the number of adherent cells.
Cat # Size Price Quantity Avail. Save
718702 10 µg 60€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
718704 25 µg 120€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

E-Selectin, an adhesion molecule, belongs to the selectin/LECAM family. E-Selectin consists of one Lectin domain and several EGF-like repeats, which are followed by a transmembrane region and a short cytoplasmic tail of 32 amino acids. E-Selectin is only expressed in endothelial cells. Upon activation by TNF-α, IL-1, and LPS, E-Selectin is upregulated at the transcriptional level and reaches the maximal peak at the cell surface in three to six hours. Then the expression level returns to the baseline after 16 to 24 hours. In contrast with P-Selectin, IL-4 suppresses the expression of E-Selectin. E-Selectin binds to its ligand ESL-1, which is a glycoprotein that is expressed in neutrophils. In addition, E-Selectin binds to PSGL-1, which interacts with P-Selectin as well. The interactions between E-Selectin and its ligands initiate cell contact and leukocyte rolling on endothelial cells’ surfaces during inflammation. E-Selectin’s expression is elevated in several types of cancer cells and contributes to cancer metastasis. Thus, in Selectin-deficient mice, metastatic breast cancer cell homing to the lung vasculature is reduced.

Product Details
Technical Data Sheet (pdf)

Product Details

Reactivity
Human
Source
Human E-Selectin, amino acids (Trp22-Pro556) (Accession# P16581), with a C-terminal human IgG1 Fc and 6-His tag was expressed in CHO cells.
Molecular Mass
The 774 amino acid recombinant protein has a predicted molecular mass of approximately 85.56 kD. The DTT-reduced and non-reduced protein migrates at approximately 100 and 200 kD respectively by SDS-PAGE. The predicted N-terminal amino acid is Trp.
Purity
>95%, as determined by Coomassie stained SDS-PAGE.
Formulation
0.22 µm filtered solution is in PBS, pH 7.2.
Endotoxin Level
Less than 0.01 ng per µg cytokine as determined by the LAL method.
Concentration
10 and 25 µg sizes are bottled at 200 µg/mL.
Storage & Handling
Unopened vial can be stored between 2°C and 8°C for one months, at -20°C for six months, or at -70°C for one year. For maximum results, quick spin vial prior to opening. Stock solutions should be prepared at no less than 50-100 µg/mL in sterile buffer (PBS, HPBS, DPBS, and EBSS) containing carrier protein such as 0.2 - 1% BSA or HSA. After dilution, the cytokine can be stored at 4°C for one month or from -20°C to -70°C for up to three months. Avoid repeated freeze/thaw cycles.
Activity
ED50 = 15 - 60 ng/mL as measured by the ability of immobilized protein to support the adhesion of U937 cells. Calcein-AM was used to measure the number of adherent cells.
Application

Bioassay

Application Notes

BioLegend carrier-free recombinant proteins provided in liquid format are shipped on blue-ice. Our comparison testing data indicates that when handled and stored as recommended, the liquid format has equal or better stability and shelf-life compared to commercially available lyophilized proteins after reconstitution. Our liquid proteins are validated in-house to maintain activity after shipping on blue ice and are backed by our 100% satisfaction guarantee. If you have any concerns, contact us at tech@biolegend.com.

Antigen Details

Structure
Adhesion molecule.
Distribution

Endothelial cells.

Function
E-Selectin mediates leukocyte rolling during inflammation.
Interaction
Neutrophils and monocytes.
Ligand/Receptor
P-selectin glycoprotein ligand-1 (PSGL-1) and ESL-1.
Cell Type
Hematopoietic stem and progenitors
Biology Area
Angiogenesis, Cell Biology, Immunology, Neuroscience, Neuroscience Cell Markers, Stem Cells
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Vestweber D, Blanks JE. 1999. Physiol. Rev. 79:181.
2. Bevilacqua MP, et al. 1987. Proc. Natl. Acad. Sci. USA 84:9238.
3. Pober JS, et al. 1987. J. Immunol. 138:3319.
4. Thornhill MH, Haskard DO. 1990. J. Immunol. 145:865.
5. Asa D, et al. 1995. J. Biol. Chem. 270:11662.
6. Fries JW, et al. 1993. Am. J. Pathol. 143:725.
7. Hiratsuka S, et al. 2011. Proc. Natl. Acad. USA 108:3725.
8. Tanaka T, et al. 2011. Adv. Mater. 36:H278-82.

Gene ID
6401 View all products for this Gene ID
UniProt
View information about E-Selectin on UniProt.org

Related FAQs

Does specific activity of a recombinant protein vary between lots?

Specific activity will vary for each lot and for the type of experiment that is done to validate it, but all passed lots will have activity within the established ED50 range for the product and we guarantee that our products will have lot-to-lot consistency. Please conduct an experiment-specific validation to find the optimal ED50 for your system.

Have your recombinants been tested for stability?

Our testing shows that the recombinant proteins are able to withstand room temperature for a week without losing activity. In addition the recombinant proteins were also found to withstand four cycles of freeze and thaw without losing activity.

How do you convert activity as an ED50 in ng/ml to a specific activity in Units/mg?
Use formula Specific activity (Units/mg) = 10e6/ ED50 (ng/mL)
How does the activity of your recombinant proteins compare to competitors?

We quality control each and every lot of recombinant protein. Not only do we check its bioactivity, but we also compare it against other commercially available recombinant proteins. We make sure each recombinant protein’s activity is at least as good as or better than the competition’s. In order to provide you with the best possible product, we ensure that our testing process is rigorous and thorough. If you’re curious and eager to make the switch to BioLegend recombinants, contact your sales representative today!

What is the specific activity or ED50 of my recombinant protein?

The specific activity range of the protein is indicated on the product datasheets. Because the exact activity values on a per unit basis can largely fluctuate depending on a number of factors, including the nature of the assay, cell density, age of cells/passage number, culture media used, and end user technique, the specific activity is best defined as a range and we guarantee the specific activity of all our lots will be within the range indicated on the datasheet. Please note this only applies to recombinants labeled for use in bioassays. ELISA standard recombinant proteins are not recommended for bioassay usage as they are not tested for these applications.

Go To Top Version: 1    Revision Date: 02.13.2017

For research use only. Not for diagnostic use. Not for resale. BioLegend will not be held responsible for patent infringement or other violations that may occur with the use of our products.

 

*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/ordering#license). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products, reverse engineer functionally similar materials, or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.

 

BioLegend Inc., 8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

Login / Register
Forgot your password? Reset password?
Create an Account