Product: APC anti-human CCR10 |
Catalog No.: 341506 |
Romy Hackbusch, miss University medical center Hamburg-Eppendorf |
APC anti-human CCR10 Gives Good Results in Flow Cytometry | |||
Overall: | Product Quality: | Ease of Use: | |
A large amount of the antibody provided good results. |
Experimental Design |
Application: | Flow Cytometry |
Cells used: | Human blood (whole) |
Brief Protocol: | 80 µl EDTA blood plus 20 µl antibody cocktail (in FACS buffer) was incubated for 30 min at RT. Erythrocytes were lysed with 1 ml of buffer, incubated for 10 min at RT, washed two times with PBS, and centrifuged at 400 x g for 5 min. Cells were re-suspended in 200-300 µl FACS buffer before undergoing analysis. CCR10-APC was titrated and applied at a final dilution of 1:50. |
Results Summary: | A large amount of antibody was needed for clear distinction. |
Additional Notes: | Gating strategy: Lymphocytes > single cells > CD3+ > CCR10+ |
|
|