Product: PE/Dazzle™ 594 anti-human CD294 (CRTH2)
Catalog No.: 350125
Romy Hackbusch, Miss University Medical Center Hamburg-Eppendorf

Anti-human CD294 (CRTH2) - PE/Dazzle™ Texas Red
Overall: Product Quality: Ease of Use:
Easy detection of CRTH2-positive cells within a CD4-population.
Experimental Design

Application: Flow Cytometry
Cells used: Human whole blood
Brief Protocol: 1. 80 µl EDTA blood plus 20 µl antibody cocktail (in FACS Buffer), incubate for 30 min at RT.
2. Lysis of erythrocytes by adding 1 ml of Lysis Buffer, incubate for 10 min at RT.
3. Wash two times with PBS; centrifuge at 400 x g for 5 min, trash supernatant.
4. Resuspend cells in 200-300 µl FACS Buffer, FACS analysis.

5. CD294-PE/Texas Red was titrated and applied at a final dilution of 1:50.
Results Summary: Usually PE/Texas Red is very bright and can be used highly diluted, but from this antibody you need quite a bit.
Additional Notes: Gating strategy: Lymphocytes > single cells > CD4+ > CD294+
Data Image

Click on the image for full size data.
Publication Status

This data has not been published.