BioLegend Product Reviews
Product: ELISA MAX™ Deluxe Set Mouse IL-12 (p70)
Catalog No.: 433604
Julia Dickow, M.Sc. Essen University Hospital

Mouse IL-12 (p70) ELISA MAX™ Deluxe
Overall: Product Quality: Ease of Use:
Good working ELISA for quantification of cytokine production.
Experimental Design

Application: ELISA
Cells used: In vitro cultured CD8 T cells with DCs
Brief Protocol: Dilute capture antibody 1:200 in 1 x coating buffer and incubate over night at 4 °C.
Next day, wash plate 4 times with 200 µl of 1 x Wash Buffer (PBS + 0,05 % Tween-20).
Block plate by adding 200 µl of Assay Diluent for 1hour.
Wash plate 4 times.
Add 100 µl diluted standards, as well as (serial-diluted) samples and incubate for 2 hours.
Wash plate 4 times.
Add 200 µl of diluted detection antibody (1:200 in Assay Diluent) and incubate for 1 hour.
Wash plate 4 times.
Add 200 µl of diluted Avidin-Antibody (1:1000 in Assay Diluent) and incubate for 30 minutes.
Wash plate 5 times.
Add 100 µl of TMB Substrate, incubate for30 minutes and then stop the reaction with 2 N H2SO4.
Measure absorbance at 570 nm (reference filter 450 nm).
Results Summary: Suitable for measurement of produced IL-12 by cells cultured in vitro.
Additional Notes:
Data Image

Click on the image for full size data.
Publication Status

This data has not been published.
See all Reviews
Related Pages:

Reviews Library
ELISA Kits and Sets
ELISA Mobile Application
Reviews Library
Multicolor Panel Selector
Fluorescence Spectra Analyzer
Fluorophore Brightness Index
Custom Panel Construction
Fluorophore Equivalency Tool
Flow Cytometry Mobile Application
Fluorescence Spectra Analyzer Mobile Application
Login/Register
Forgot your password? Reset Password
Request an Account