Welcome to BioLegend’s one-of-a-kind advanced search. Search by any one of the single fields below or narrow down your searches by using multiple parameters. Looking for an anti-mouse NK cell antibody for IHC? Or looking for a FITC-conjugated antibody against a human marker for dendritic cells to use for flow cytometry? Only BioLegend’s advanced search can provide you with the best answers. If you have further questions, please contact our technical service team at 858-768-5801.
Catalog Number
Specificity
GeneID
Clone
Format
Species Reactivity
Applications
Cell Type
Keywords
*To perform a multi-parameter search, be sure to click on "Match all fields" below:
Match all fields
Match any field
Exact match
Partial match
Use this document lookup tool to find Current Product Datasheets, Certificates of Analysis, or MSDS for any antibody products you have purchased from BioLegend.
Use the search box below to perform a site search of BioLegend.com powered by Google™.
The antibody was purified by affinity chromatography, and conjugated with biotin under optimal conditions. The solution is free of unconjugated biotin.
Concentration:
0.5 mg/ml
Storage & Handling:
The antibody solution should be stored undiluted at 4°C. Do not freeze.
Each lot of this antibody is quality control tested by ELISA assay. For ELISA capture applications, a concentration range of 0.5-2 μg/ml is recommended. It is recommended that the reagent be titrated for optimal performance for each application.
COA:
Enter Lot#:
Application Notes:
ELISA Detection: The biotinylated Poly5095 antibody is useful as the detection antibody in a sandwich ELISA assay, when used in conjunction with the purified JK1RA-1 (Cat. No. 509902) antibody as the capture antibody.
Interleukin-1 receptor antagonist (IL-1RA) is composed of three isoforms, one secreted (sIL-1Rα/IL-1Rα1), two intracellular (IL-1Rα2/IL-1Rα3) and produced by monocytes, tissue macrophages, Langerhans cells, dendritic cells, T and B cells, natural killer (NK) cells, large granular lymphocytes (LGL), vascular endothelium, smooth muscle, fibroblasts, thymic epithelia, astrocytes, microglia, glioma cells, keratinocytes, and chondrocytes. It is upregulated by IL-1β, IL-4, IL-6 and downregulated by glucocorticoids. The Poly5095 polyclonal antibody reacts with human interleukin-1 receptor antagonist (IL-1RA).
Cytokine; three isoforms, one secreted (sIL-1Rα/IL-1Rα1), two intracellular (IL-1Rα2/IL-1Rα3); 17 kD (Mammalian)
Regulation:
Upregulated by IL-1β, IL-4, IL-6; downregulated by glucocorticoids
Cellular Sources:
Monocytes, tissue macrophages, Langerhans cells, dendritic cells, T and B cells, natural killer (NK) cells, large granular lymphocytes (LGL), vascular endothelium, smooth muscle, fibroblasts, thymic epithelia, astrocytes, microglia, glioma cells, keratino
Cellular Targets:
B cells, T cells, monocytes
Receptors:
Type I IL-1R (CDw121a), Type II IL-1R (CDw121b)
Bioactivity/Activities:
Storage forms that are released upon cell death to limit inflammation caused by cell debris; competitive inhibitor of IL-1 receptor binding; antagonizes IL-1 activities without having agonist effects; does not initiate intracellular signal transduction pr
Antigen References:
1. Carter D, et al. 1990. Nature 344:633. 2. Chirivi R, et al. 1993. Cancer Res. 53:5051. 3. Holtkamp G, et al. 1999. Eur. J. Immunol. 29:215. 4. Kim J, et al. 2003. Gene Ther. 10:1543.
*These products may be covered by one or more Limited Use Label Licenses (see the BioLegend Catalog or our website, www.biolegend.com/terms). BioLegend products may not be transferred to third parties, resold, modified for resale, or used to manufacture commercial products or to provide a service to third parties without written approval of BioLegend. By use of these products you accept the terms and conditions of all applicable Limited Use Label Licenses. Unless otherwise indicated, these products are for research use only and are not intended for human or animal diagnostic, therapeutic or commercial use.
This data display is provided for general comparisons between formats. Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors. If you need assistance with selecting the best format contact our expert technical support team.